Difference between revisions of "Hydrophones"
From Beam Reach Wiki
(→Beam Reach hydrophones) |
(→Beam Reach hydrophones) |
||
Line 17: | Line 17: | ||
*** [[Image:Labcore40.png|200px|LabCore 40]] Lab40 (one of Marla Holt's, but same model as those used by Beam Reach; by Joe Olson at Keyport facility) | *** [[Image:Labcore40.png|200px|LabCore 40]] Lab40 (one of Marla Holt's, but same model as those used by Beam Reach; by Joe Olson at Keyport facility) | ||
*** [[Image:C54xr-266-freq-resp-log-100db-lg.jpg|200px|C54XRS]] C54XRS (from Cetacean Research Technologies; calibrated by Joe Olson at Keyport facility) | *** [[Image:C54xr-266-freq-resp-log-100db-lg.jpg|200px|C54XRS]] C54XRS (from Cetacean Research Technologies; calibrated by Joe Olson at Keyport facility) | ||
− | *** [[Image:HTI-99-HF.png|200px|HTI99HF]] HTI-99-HF (from High Tech, Inc; calibrated by U.S. Navy in Newport, RI facility) | + | *** [[Image:HTI-99-HF.png|200px|HTI99HF]] HTI-99-HF (from High Tech, Inc; calibrated by U.S. Navy in Newport, RI facility; [http://www.beamreach.org/wiki/images/0/0a/Cal_Memo_4167.PDF full report as a PDF]) |
==Wish list of other hydrophones== | ==Wish list of other hydrophones== |
Revision as of 11:29, 21 February 2019
Beam Reach hydrophones
- Arrays
- 4-element linear array (Lab40 model from LabCore Systems, Lon Brockelhurst) Though these are not calibrated, they are the same model as the elements in a similar array that was calibrated by Marla Holt. (Add her calibration curves here?)
- 8-element beamforming array from Mike Dougherty (not operational)
- Single hydrophones (this should probably become or be supplemented by a Google spreadsheet)
- Uncalibrated
- ITCs (towed single and in Orcasound array)
- other CRTs
- salvaged Navy sonobuoy single elements
- miscellaneous single elements (donated by Mike Dougherty)
- etc...
- Uncalibrated
- Calibrated (see response curves below)
- Interoceans (used courtesy Colorado College; calibrated by Joe Olson at Keyport facility)
- Reson TC4032 (deployed 2009 at Lime Kiln with The Whale Museum, Spec sheet for Reson TC4032)
- Lab40 (one of Marla Holt's, but same model as those used by Beam Reach; by Joe Olson at Keyport facility)
- C54XRS (from Cetacean Research Technologies; calibrated by Joe Olson at Keyport facility)
- HTI-99-HF (from High Tech, Inc; calibrated by U.S. Navy in Newport, RI facility; full report as a PDF)
- Calibrated (see response curves below)
Wish list of other hydrophones
(Will review above as we try these out...)
- Hydrophone comparison matrix, including frequency ranges and dated price quotes
- Naxys eHyd digital hydrophone (Expensive! APL paid ~$13k in ~2007/8)